ASTM C1685 工业用气动高温纤维保温材料规范标准
日期:2012-02-13 21:33
sed chemical binder.
1.3 The pneumatically applied, high-temperature fiber insulation is intended for use in industrial applications on flat, or nearly flat, surfaces. It is not intended for use on pipes.
1.4 This specification does not address the requirements for fire-resistive insulation, but it does not preclude this materials use in that capacity.
1.5 This is a material specification only and is not intended to cover methods of application that are provided by the manufacturer.
1.6 The valu