ASTM F479绝缘涂层在使用中维护的标准使用规范

放大字体  缩小字体 发布日期:2012-02-08   浏览次数:40  分享到: 分享到腾讯微博
ASTM F479绝缘涂层在使用中维护的标准使用规范
ASTM F479 Standard Specification for In-Service Care of Insulating Blankets
ASTM F479绝缘涂层在使用中维护的标准使用规范
This specification covers elastomeric seals (gaskets) used to seal the joints of plastic pipe used for gravity, low-pressure, and high-pressure applications. This refers to push-on joints which require no internal or external pressure to effect the initial seal. Tensile strength, elongation, hardness, compression set, accelerated aging, water immersion, ozone resistance, and force decay shall be tested to meet the requirements prescribed.This specification covers the in-service care, inspection, testing, and use voltage of insulating blankets for protection of workers from accidental contact with live electrical conductors, apparatus, or circuits. Blankets covered shall be designated as type I or type II; class 0, class 1, class 2, class 3, or class 4; style A or style B: type I - not resistant to ozone, made from a high-grade cis-1,4-polyisoprene rubber compound of natural or synthetic origin, properly vulcanized; and type II - ozone-resistant, made of any elastomer or combination of elastomeric compounds. Style A - constructed of the elastomers indicated under type I or type II, shall be free of any reinforcement; and style B - constructed of the elastomers indicated under type I or type II, shall incorporate a reinforcement. Electrical testing shall be performed to meet the requirements prescribed.
This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.
1. Scope
1.1 This specification covers the in-service care, inspection, testing, and use voltage of insulating blankets for protection of workers from accidental contact with live electrical conductors, apparatus, or circuits. The product requirements and acceptance testing are as shown in Specification D 1048.
This standard does not purport to address all of the safety problems, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. See Section 6 and for specific precautionary statements.

2. Referenced Documents (purchase separately)
ASTM Standards
D1048 Specification for Rubber Insulating Blankets
D2865 Practice for Calibration of Standards and Equipment for Electrical Insulating Materials Testing
F819 Terminology Relating to Electrical Protective Equipment for Workers
ANSI Standard
C84.1 Voltage Ratings for Electric Power Systems and Equipment (60 Hz)
Index Terms
electrical insulating blankets; lineman; lineman protective equipment;


  详情请咨询
  防火资源网-阻燃防火测试中心
  电话:(+86)0592-5056213
  传真:(+86)0592-5105807
  邮件:firetest@firetc.com

凡注明"防火资源网"的所有作品,由<防火资源网>整理编辑,任何组织未经<防火资源网>及其拥有者授权,不得复制、转载、摘编或利用其它方式应用于任何商业行为。

 
 
[ 防火测试中心搜索 ]  [ ]  [ 告诉好友 ]  [ 打印本文 ]  [ 关闭窗口 ]  [ 返回顶部 ]

 

 
 
推荐防火测试
推荐图文
点击排行
 
 
网站首页 | 广告服务 | 关于我们 | 联系方式 | 服务协议 | 版权声明 | 网站地图 | 友情链接 | 网站留言 | 旧版本 | 闽ICP备09009213号
©2019-2021 FIRETC.COM All Rights Reserved   备案号:闽ICP备09009213号-1在线客服 点击QQ交谈/留言 点击QQ交谈/留言