阻燃防火材料-网上贸易平台 | | WAP浏览
服务热线:4006555305
当前位置: 首页 » 防火测试中心 » 各国标准法规 » 美国 » 正文

ASTM D7307通过微量燃烧热量测定法测定塑料和其它实心材料燃烧性能的试验方法

放大字体  缩小字体 发布日期:2012-02-08   浏览次数:217  分享到: 分享到腾讯微博
ASTM D7309通过微量燃烧热量测定法测定塑料和其它实心材料燃烧性能的试验方法
ASTM D7295 Standard Practice for Sampling and Determination of Hydrogen Cyanide (HCN) in Combustion Effluents and Other Stationary Sources
ASTM D7295 燃烧排出液和其它固定源中氢氰酸的取样及测定规程


Hydrogen cyanide is highly toxic. In relatively low quantities, hydrogen cyanide can cause asphyxia and death.
The National Fire Protection Association has assigned a flammability rating of 4 (severe fire hazard) to hydrogen cyanide.
1. Scope
1.1 This practice is used to determine the concentration of gaseous hydrogen cyanide (HCN) from any combustion device or atmosphere where cyanide may be present. While primarily designed for the measurement of gas phase HCN, the sample collection described in this practice also includes cyanide ion (CN-) absorbed particles that may be present in the sampling atmosphere.
1.1.1 Samples can be collected from a closed chamber such as the NBS smoke box described in Test Method E662 provided it is equipped with sampling ports.
1.1.2 Open chambers such as industrial work areas or large scale fires can be monitored for HCN with this practice.
1.1.3 The HCN emissions of a flow through system can be determined by sampling from its discharge stack. Examples of such systems include large scale manufacturing applications and the cone calorimeter described in Test Method E1354.
1.2 This practice can be used to monitor HCN levels in lab scale fire smoke effluents in order to estimate toxicity of gases produced from burning materials. See Guide E800.
1.3 The concentration range of hydrogen cyanide will be dependent on the volume of gas sampled, the volume of sodium hydroxide solution placed in the impinger during sampling, and the analytical method used to measure cyanide. For example, the lower limit of detection would be 0.002-mg/m3 when 0.1-m3 of combustion effluent is collected into 100-mL sodium hydroxide solution based on a detection limit of 0.002 mg/L cyanide in the impinger solution when using the flow injection analysis (FIA) system described in Test Method D6888.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

2. Referenced Documents (purchase separately
ASTM Standards
D1193 Specification for Reagent Water
D1356 Terminology Relating to Sampling and Analysis of Atmospheres
D2036 Test Methods for Cyanides in Water
D2777 Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water
D3154 Test Method for Average Velocity in a Duct (Pitot Tube Method)
D3614 Guide for Laboratories Engaged in Sampling and Analysis of Atmospheres and Emissions
D3685/D3685M Test Methods for Sampling and Determination of Particulate Matter in Stack Gases
D4841 Practice for Estimation of Holding Time for Water Samples Containing Organic and Inorganic Constituents
D5337 Practice for Flow Rate Calibration of Personal Sampling Pumps
D6696 Guide for Understanding Cyanide Species
D6888 Test Method for Available Cyanide with Ligand Displacement and Flow Injection Analysis (FIA) Utilizing Gas Diffusion Separation and Amperometric Detection
D7365 Practice for Sampling, Preservation and Mitigating Interferences in Water Samples for Analysis of Cyanide
E337 Test Method for Measuring Humidity with a Psychrometer (the Measurement of Wet- and Dry-Bulb Temperatures)
E662 Test Method for Specific Optical Density of Smoke Generated by Solid Materials
E800 Guide for Measurement of Gases Present or Generated During Fires
E1354 Test Method for Heat and Visible Smoke Release Rates for Materials and Products Using an Oxygen Consumption Calorimeter
Index Terms
amperometry; combustion gases; cyanide; fire gases; flow injection analysis; hydrogen cyanide; stack emissions; workplace monitoring; Combustion; Effluents; Hydrogen cyanide;

  详情请咨询
  防火资源网-阻燃防火测试中心
  电话:(+86)0592-5056213
  传真:(+86)0592-5105807
  邮件:firetest@firetc.com

凡注明"防火资源网"的所有作品,由<防火资源网>整理编辑,任何组织未经<防火资源网>及其拥有者授权,不得复制、转载、摘编或利用其它方式应用于任何商业行为。

 
 
[ 防火测试中心搜索 ]  [ ]  [ 告诉好友 ]  [ 打印本文 ]  [ 关闭窗口 ]  [ 返回顶部 ]

 

 
 
推荐防火测试
推荐图文
点击排行
 
 
网站首页 | 广告服务 | 关于我们 | 联系方式 | 服务协议 | 版权声明 | 网站地图 | 友情链接 | 网站留言 | 旧版本 | 闽ICP备09009213号
©2019-2021 FIRETC.COM All Rights Reserved   备案号:闽ICP备09009213号-1在线客服 点击QQ交谈/留言 点击QQ交谈/留言