ASTM F2321  Standard Specification for Flexible Insulated Temporary By-Pass Jumpers
ASTM F2321柔性绝缘临时旁路跳线的标准规范
These specifications provides the manufacture and testing, as well as individual design, electrical, mechanical, and workmanship requirements for a system of flexible insulated temporary bypass jumpers used on energized power lines and equipment. These specifications for a system of bypass jumpers are covered in four parts as follows: clamps for bypass jumpers; ferrules for bypass jumpers; cable for bypass jumpers; and bypass jumpers (complete assembly with clamps, ferrules, and cable). The use and maintenance of these equipments are not addressed in these specifications.
This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.
1. Scope
1.1 These specifications cover the manufacture and testing of flexible insulated temporary bypass jumpers (bypass jumpers) used on energized power lines and equipment.
1.2 It is common practice for the user of this protective equipment to prepare complete instructions and safety regulations to govern in detail the correct and safe use of such equipment. Also see .
1.3 The use and maintenance of this equipment are beyond the scope of these specifications.
1.4 These specifications for a system of bypass jumpers is covered in four parts as follows:
Title    Sections
Clamps for Bypass Jumpers   
Ferrules for Bypass Jumpers   
Cable for Bypass Jumpers   
Bypass Jumpers (complete assemblywith clamps, ferrules, and cable)   
1.5 Each of the four parts is an entity of itself, but is listed as a part of the system for completeness and clarification.
1.6 The values stated in SI units are to be regarded as the standard. See ASTM SI 10.
The following precautionary caveat pertains only to the test method portions, Sections , , , and of these specifications. This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.

2. Referenced Documents (purchase separately)
ASTM Standards
B33 Specification for Tinned Soft Annealed Copper Wire for Electrical Purposes
B172 Specification for Rope-Lay-Stranded Copper Conductors Having Bunch-Stranded Members, for Electric Conductors
B173 Specification for Rope-Lay-Stranded Copper Conductors Having Concentric-Stranded Members, for Electrical Conductors
D2768 Specification for General-Purpose Ethylene-Propylene Rubber Jacket for Wire and Cable
D2770 Specification for Ozone-Resisting Ethylene-Propylene Rubber Integral Insulation and Jacket for Wire and Cable
D2802 Specification for Ozone-Resistant Ehtylene-Alkene Polymer Insulation for Wire and Cable
D2865 Practice for Calibration of Standards and Equipment for Electrical Insulating Materials Testing
E8 Test Methods for Tension Testing of Metallic Materials
F819 Terminology Relating to Electrical Protective Equipment for Workers
SI10 Practice for Use of the International System of Units (SI) (the Modernized Metric System)
ANSI Standard
ANSIC119.4 American National Standard for Electrical Connectors
NEMA Standard
WC8 Ethylene-Propylene-Rubber Insulated Wire and Cable for the Transmission and Distribution of Electrical Energy (formerly ICEA S-68-516)
Index Terms
bypass jumpers; lineman; lineman protective equipment;


  详情请咨询
  防火资源网-阻燃防火测试中心
  电话:(+86)0592-5056213
  传真:(+86)0592-5105807
  邮件:firetest@firetc.com

凡注明"防火资源网"的所有作品,由<防火资源网>整理编辑,任何组织未经<防火资源网>及其拥有者授权,不得复制、转载、摘编或利用其它方式应用于任何商业行为。

 
 
[ 防火测试中心搜索 ]  [ ]  [ 告诉好友 ]  [ 打印本文 ]  [ 关闭窗口 ]  [ 返回顶部 ]

 

 
 
推荐防火测试
推荐图文
点击排行
 
 
网站首页 | 广告服务 | 关于我们 | 联系方式 | 服务协议 | 版权声明 | 网站地图 | 友情链接 | 网站留言 | 旧版本 | 闽ICP备09009213号
©2019-2021 FIRETC.COM All Rights Reserved   备案号:闽ICP备09009213号-1在线客服 点击QQ交谈/留言 点击QQ交谈/留言