ASTM D619 Standard Test Methods for Vulcanized Fibre Used for Electrical Insulation
ASTM D619电绝缘用硫化纤维标准试验方法

These test methods details the standard procedures for testing certain properties of vulcanized fibre sheets, tubes, and rods of such grades as can be used for electrical insulation. Arc resistance, ash content, bond strength (ply adhesion), bursting strength, compressive strength, conditioning, density, dielectric strength, dimensional measurements, flammability, flexural strength, silica content, tearing strength, tensile strength, thickness (for sheets), resistance to impact, Rockwell hardness, volatile matter content, water absorption, and zinc chloride content are among the properties that these test methods shall be able to examine.
This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.
1. Scope
1.1 These test methods cover the procedures for testing vulcanized fibre sheets, tubes, and rods of such grades as can be used for electrical insulation.
1.2 The procedures appear in the following sections:
ProcedureSection
Arc resistance
Ash
Bond strength (ply adhesion)
Bursting strength
Compressive strength, ,
Conditioning
Density, ,
Dielectric strength,
Dimensional measurements,
Flammability
Flexural strength,
Silica
Tearing strength
Tensile strength, ,
Thickness (sheets)
Resistance to impact
Rockwell hardness
Volatile matter
Water absorption
Zinc chloride
1.3 The values stated in inch-pound units are to be regarded as the standard. The SI values given in parentheses are for information only.
This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in and .
Note 1
The test methods described herein are similar technically to those described in IEC Publication 60667-2. Not all of the tests in this document are included in IEC 60667-2, and the procedures in the two publications are not completely identical; but it is expected that comparable results will be obtained from most of the procedures and comparative tests should be made if necessary before directly comparing results of tests using the different procedures.

2. Referenced Documents (purchase separately)
ASTM Standards
D149 Test Method for Dielectric Breakdown Voltage and Dielectric Strength of Solid Electrical Insulating Materials at Commercial Power Frequencies
D202 Test Methods for Sampling and Testing Untreated Paper Used for Electrical Insulation
D229 Test Methods for Rigid Sheet and Plate Materials Used for Electrical Insulation
D256 Test Methods for Determining the IZOD Pendulum Impact Resistance of Plastics
D348 Test Methods for Rigid Tubes Used for Electrical Insulation
D349 Test Methods for Laminated Round Rods Used for Electrical Insulation
D374 Test Methods for Thickness of Solid Electrical Insulation
D495 Test Method for High-Voltage, Low-Current, Dry Arc Resistance of Solid Electrical Insulation
D570 Test Method for Water Absorption of Plastics
D668 Test Methods of Measuring Dimensions of Rigid Rods and Tubes Used for Electrical Insulation
D689 Test Method for Internal-Tearing Resistance of Paper
D695 Test Method for Compressive Properties of Rigid Plastics
D785 Test Method for Rockwell Hardness of Plastics and Electrical Insulating Materials
D792 Test Methods for Density and Specific Gravity (Relative Density) of Plastics by Displacement
D828 Test Method for Tensile Properties of Paper and Paperboard Using Constant-Rate-of-Elongation Apparatus
D952 Test Method for Bond or Cohesive Strength of Sheet Plastics and Electrical Insulating Materials
D1711 Terminology Relating to Electrical Insulation
D6054 Practice for Conditioning Electrical Insulating Materials for Testing
IEC Standard
IEC60667-2 Specification for Vulcanized Fibre for Electrical Purposes-Part 2: Methods of Test
Index Terms
arc resistance; ash content; bond strength; bursting strength; compressive strength; density; dielectric strength; flame resistance; flexural strength; impact resistance; inside diameter; outside diameter; ply adhesion; rigid rods; rigid sheets; rigid tubes; Rockwell hardness; silica content; tear resistance (internal); tensile strength; thickness; volatile content; vulcanized fibre; wall thickness; water absorption; zinc chloride content

  详情请咨询
  防火资源网-阻燃防火测试中心
  电话:(+86)0592-5056213
  传真:(+86)0592-5105807
  邮件:firetest@firetc.com

凡注明"防火资源网"的所有作品,由<防火资源网>整理编辑,任何组织未经<防火资源网>及其拥有者授权,不得复制、转载、摘编或利用其它方式应用于任何商业行为。

 
 
[ 防火测试中心搜索 ]  [ ]  [ 告诉好友 ]  [ 打印本文 ]  [ 关闭窗口 ]  [ 返回顶部 ]

 

 
 
推荐防火测试
推荐图文
点击排行
 
 
网站首页 | 广告服务 | 关于我们 | 联系方式 | 服务协议 | 版权声明 | 网站地图 | 友情链接 | 网站留言 | 旧版本 | 闽ICP备09009213号
©2019-2021 FIRETC.COM All Rights Reserved   备案号:闽ICP备09009213号-1在线客服 点击QQ交谈/留言 点击QQ交谈/留言