This specification covers semirigid, flame-retardant, crosslinked poly(vinylidene fluoride) heat-shrinkable tubing for electrical insulation purposes. It is supplied in an expanded form and will shrink to its extruded diameter when heated. The tubing shall be extruded, crosslinked, and then expanded to the required dimensions. The material shall conform to the chemical property requirements specified. Every lot of material manufactured shall be tested for restricted shrinkage, heat shock, tensile strength, and elongation to conform to the mechanical, thermal, electrical requirements.
This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.
1. Scope
1.1 This specification covers semirigid, flame-retardant, crosslinked poly(vinylidene fluoride) heat-shrinkable tubing for electrical insulation purposes. It is supplied in an expanded form and will shrink to its extruded diameter when heated.
Note 1
This standard is similar but not identical to IEC 60684-3-228.
1.2 The values stated in inch-pound units are to be regarded as the standard, except temperature which shall be stated in degrees Celsius. Values in parentheses are for information only.
2. Referenced Documents (purchase separately)
ASTM Standards
D910 Specification for Aviation Gasolines
D1711 Terminology Relating to Electrical Insulation
D2671 Test Methods for Heat-Shrinkable Tubing for Electrical Use
D3636 Practice for Sampling and Judging Quality of Solid Electrical Insulating Materials
E176 Terminology of Fire Standards
Military Standards
MIL-A-8243 Anti-Icing and Deicing--Defrosting Fluid
Federal Standards
SS-S-550 Sodium Chloride, Technical, for Water-Softening Units
IEC Standards
60684–3– Flexible insulating sleeving, Part 3, Sheet 228: Heat-shrinkable, semi-rigid, polyvinylidene fluoride sleeving, flame retarded, fluid resistant, shrink ratio 2:1
Index Terms
crosslinked poly(vinylidene fluoride) heat-shrinkable tubing; electrical insulation; heat-shrinkable tubing; poly(vinylidene fluoride);
 

  详情请咨询
  防火资源网-阻燃防火测试中心
  电话:(+86)0592-5056213
  传真:(+86)0592-5105807
  邮件:firetest@firetc.com

凡注明"防火资源网"的所有作品,由<防火资源网>整理编辑,任何组织未经<防火资源网>及其拥有者授权,不得复制、转载、摘编或利用其它方式应用于任何商业行为。

 
 
[ 防火测试中心搜索 ]  [ ]  [ 告诉好友 ]  [ 打印本文 ]  [ 关闭窗口 ]  [ 返回顶部 ]

 

 
 
推荐防火测试
推荐图文
点击排行
 
 
网站首页 | 广告服务 | 关于我们 | 联系方式 | 服务协议 | 版权声明 | 网站地图 | 友情链接 | 网站留言 | 旧版本 | 闽ICP备09009213号
©2019-2021 FIRETC.COM All Rights Reserved   备案号:闽ICP备09009213号-1在线客服 点击QQ交谈/留言 点击QQ交谈/留言