1.1* Scope.
1.1.1 This code shall apply to motor fuel dispensing facilities; marine/motor fuel dispensing facilities; and motor fuel dispensing facilities located inside buildings, at fleet vehicle motor fuel facilities, and at farms and isolated construction sites. This code shall also apply to motor vehicle repair garages.
1.1.2* This code shall not apply to those motor fuel dispensing facilities where only liquefied petroleum gas (LP-Gas), liquefied natural gas (LNG), or compressed natural gas (CNG) is dispensed as motor fuel.
A.1.1.2 See NFPA 52, Vehicular Fuel Systems Code, and NFPA 58, Liquefied Petroleum Gas Code, for requirements for facilities where only these fuels are dispensed.
A.1.1 This code, known as the Code for Motor Fuel Dispensing Facilities and Repair Garages, is recommended for use as the basis for legal regulations. Its provisions are intended to reduce the hazards of motor fuels to a degree consistent with reasonable public safety, without undue interference with public convenience and necessity. Thus, compliance with this code does not eliminate all hazards in the use of these fuels. See the Flammable and Combustible Liquids Code Handbook for additional explanatory information.
 
 
Improve fire safety in service stations and repair facilities with the critical guidelines outlined in the 2012 edition of NFPA 30A.
Service stations dispensing flammable fuels can avoid serious hazards only by adhering to specialized guidelines. The 2012 NFPA 30A: Code for Motor Fuel Dispensing Facilities and Repair Garages provides the latest rules for piping, fuel dispensing systems, service stations inside buildings, and operations for retail fuel dispensing and fleet vehicle fuel dispensing.
Changes in this updated edition include:
·   New 6.3.6, Inspection and Maintenance, addresses inspection, maintenance, and repair of fuel dispensing equipment, leak detection equipment, and secondary containment equipment.
·   New 6.6.1.1 requires that any modification of the dispensing nozzle be either listed or be approved by the manufacturer of the nozzle.
·   Amended Subsection 6.6.1 requires that all dispensing nozzles, except those used for marine fuel dispensing, have a latch-open device.
·   New 7.4.7.4 requires that the circuits of gas detection systems required for repair garages be monitored for integrity in accordance with NFPA 72®: National Fire Alarm and Signaling Code.
·   Revised Section 12.5, Specific Requirements for LP-Gas Dispensing Devices, eliminates a conflict with NFPA 58: Liquefied Petroleum Gas Code.
Work safely with revised Chapter 8, Electrical Installations.
Extensively revised and updated, NFPA 30A's Chapter 8 incorporates a new Table 8.3.1 that includes criteria for the Zone system for area classification, a revised drawing that depicts the extent of area classification around fuel dispensing units, and a new diagram depicting the extent of area classification around tank-mounted fuel dispensing units.
Today's NFPA 30A is an essential resource for architects and engineers involved with design and construction of motor fuel dispensing facilities, AHJs and other professionals with oversight/review authority, and facility owners and operators. (Softbound, 40 pp., 2012)
 

  详情请咨询
  防火资源网-阻燃防火测试中心
  电话:(+86)0592-5056213
  传真:(+86)0592-5105807
  邮件:firetest@firetc.com

凡注明"防火资源网"的所有作品,由<防火资源网>整理编辑,任何组织未经<防火资源网>及其拥有者授权,不得复制、转载、摘编或利用其它方式应用于任何商业行为。

 
 
[ 防火测试中心搜索 ]  [ ]  [ 告诉好友 ]  [ 打印本文 ]  [ 关闭窗口 ]  [ 返回顶部 ]

 

 
 
推荐防火测试
推荐图文
点击排行
 
 
网站首页 | 广告服务 | 关于我们 | 联系方式 | 服务协议 | 版权声明 | 网站地图 | 友情链接 | 网站留言 | 旧版本 | 闽ICP备09009213号
©2019-2021 FIRETC.COM All Rights Reserved   备案号:闽ICP备09009213号-1在线客服 点击QQ交谈/留言 点击QQ交谈/留言