NFPA 150 赛场马厩的消防安全标准

放大字体  缩小字体 发布日期:2012-02-08   浏览次数:59  分享到: 分享到腾讯微博
NFPA 150 赛场马厩的消防安全标准

NFPA 150 Standard on Fire and Life Safety in Animal Housing Facilities
NFPA 150 赛场马厩的消防安全标准

 

1.1 Scope.

1.1.1* This standard shall provide the minimum requirements for the design, construction, fire protection, and classification of animal housing facilities.

A.1.1.1 The requirements of NFPA 150 recognize the following fundamental principles

(1) Animals are sentient beings with a value greater than that of simple property.

(2) Animals, both domesticated and feral, lack the ability of 0self-preservation when housed in buildings and other structures.

(3) Current building, fire, and life safety codes do not address the life safety of the animal occupants. The requirements found in NFPA 150 are written with the intention that animal housing facilities will continue to be designed, constructed, and maintained in accordance with the applicable building, fire, and life safety codes. The requirements herein are not intended to replace or rewrite the basic requirements for the human occupants. Instead, NFPA 150 provides additional minimum requirements for the protection of the animal occupants and the human occupants who interact with those animals in these facilities. NFPA 150 is divided into three major sections The first section, Chapters 1 through 3, contains only administrative requirements, while the second section, Chapters 4 through 10, provides general requirements for all facilities housing animals (i.e., facility subclassification, animal category, construction, means of egress, fire protection, and interior finish requirements), and the third section, Chapters 11–13, includes specific requirements focused on the class of the facility.

1.1.2 Animal housing facilities shall be designed, constructed, and maintained in accordance with the adopted building, fire, and life safety codes and the requirements herein.

1.1.3 Where requirements of this standard differ from the adopted fire prevention, life safety, and building codes, the requirements of this standard shall govern the protection of the animal occupants and animal handlers.

 

 

Apply industry best practices for safety in animal housing facilities with the 2009 NFPA 150!

Improve health and welfare of animals while protecting human life and property with the 2009 NFPA 150 Standard on Fire and Life Safety in Animal Housing Facilities. This Standard covers all types of animal housing facilities where animals are kept for any purpose, including barns, stable, kennels, animal shelters, veterinary facilities, zoos, laboratories, and racetracks. The Standard is divided into three major sections

·   Section 1 (Chapters 1-3) contains administrative requirements

·   Section 2 (Chapters 4-10) provides general requirements for all facilities housing animals

·   Section 3 (Chapters 11-13) includes specific requirements focused on the class of the facility

Updated to respond to industry developments and trends, changes in the 2009 NFPA 150 include

·   Clarifications regarding the use of Quick Response Sprinklers in areas allowed by NFPA 13

·   Recognition of various type of smoke control/management systems and allows numerous detection options for initiating the operation of the system

·   New options to utilize different fire test protocols to determine flame spread and fire behavior characteristics of interior finish materials.

(Softbound, 26 pp., 2009)


  详情请咨询
  防火资源网-阻燃防火测试中心
  电话:(+86)0592-5056213
  传真:(+86)0592-5105807
  邮件:firetest@firetc.com

凡注明"防火资源网"的所有作品,由<防火资源网>整理编辑,任何组织未经<防火资源网>及其拥有者授权,不得复制、转载、摘编或利用其它方式应用于任何商业行为。

 
 
[ 防火测试中心搜索 ]  [ ]  [ 告诉好友 ]  [ 打印本文 ]  [ 关闭窗口 ]  [ 返回顶部 ]

 

 
 
推荐防火测试
推荐图文
点击排行
 
 
网站首页 | 广告服务 | 关于我们 | 联系方式 | 服务协议 | 版权声明 | 网站地图 | 友情链接 | 网站留言 | 旧版本 | 闽ICP备09009213号
©2019-2021 FIRETC.COM All Rights Reserved   备案号:闽ICP备09009213号-1在线客服 点击QQ交谈/留言 点击QQ交谈/留言