ASTM F1134船用电动机及发电机绝缘电阻监测仪的规格

放大字体  缩小字体 发布日期:2012-02-08   浏览次数:41  分享到: 分享到腾讯微博
ASTM F1134船用电动机及发电机绝缘电阻监测仪的规格
ASTM F1134 Standard Specification for Insulation Resistance Monitor for Shipboard Electrical Motors and Generators
ASTM F1134船用电动机及发电机绝缘电阻监测仪的规格

This specification covers monitoring devices (monitors) for the automatic detection and signaling of low insulation resistance values in idle electrical motors or generators, or both. Monitors are intended for permanent installation in both existing or new panels and controller enclosures designed for marine application. These insulation resistance monitors shall be classified in four types: Type I are alternating current generator monitors, Type II are alternating current generator monitors, Type III are direct current motor monitors, and Type IV are direct current generator monitors. The enclosure materials used in the construction of the monitors are to be flame-retardant and the current carrying terminals shall be made of corrosion resistant material. The monitors shall isolate their measuring circuit from the line voltage, while the motor is operating, by the use of an integral isolating relay. In the design of these monitors, environmental factors shall be considered: operating temperature range, sealing, inclination, humidity, and vibration. Also, the monitor relays, voltage characteristics and operating accuracy shall be considered in the design of these monitors. Each monitor shall be subjected to the following: visual and mechanical examination and operational test.
This abstract is a brief summary of the referenced standard. It is informational only and not an official part of the standard; the full text of the standard itself must be referred to for its use and application. ASTM does not give any warranty express or implied or make any representation that the contents of this abstract are accurate, complete or up to date.
1. Scope
1.1 This specification covers monitoring devices (monitors) for the automatic detection and signaling of low insulation resistance values in idle electrical motors or generators, or both.
1.2 Monitors are intended for permanent installation in both existing or new panels and controller enclosures designed for marine application.
1.3 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.
The following safety hazards caveat pertains only to the test method described in this specification: This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

2. Referenced Documents (purchase separately)
UL Standard
UL94 Test for Flammability of Plastic Materials for Parts in Devices and Appliances
IEEE Standards
IEEE100 Standard Dictionary of Electrical and Electronics Terms
Government Standard
Title46 Code of Federal Regulations Shipping
Index Terms
electrical generator; electrical motors; insulation; low insulation resistance values; marine controller enclosures; resistance monitor; shipboard generator; shipboard motors;

  详情请咨询
  防火资源网-阻燃防火测试中心
  电话:(+86)0592-5056213
  传真:(+86)0592-5105807
  邮件:firetest@firetc.com

凡注明"防火资源网"的所有作品,由<防火资源网>整理编辑,任何组织未经<防火资源网>及其拥有者授权,不得复制、转载、摘编或利用其它方式应用于任何商业行为。

 
 
[ 防火测试中心搜索 ]  [ ]  [ 告诉好友 ]  [ 打印本文 ]  [ 关闭窗口 ]  [ 返回顶部 ]

 

 
 
推荐防火测试
推荐图文
点击排行
 
 
网站首页 | 广告服务 | 关于我们 | 联系方式 | 服务协议 | 版权声明 | 网站地图 | 友情链接 | 网站留言 | 旧版本 | 闽ICP备09009213号
©2019-2021 FIRETC.COM All Rights Reserved   备案号:闽ICP备09009213号-1在线客服 点击QQ交谈/留言 点击QQ交谈/留言